Manager BOM: fix ENC1, F1 and BZ1 part numbers - #10
Merged
Merged
Conversation
- ENC1: C2831776 was a 100 uF/50 V electrolytic, not an encoder. Now Alps EC11E18244A5 (C255515), the EC11E with push switch the footprint is for. - F1: C3207114 was a 6.35 mm cylindrical fuse clip. The land is a direct-solder MINI blade, so F1 is now the 2 A fuse itself, Littelfuse 0297002.WXNV (C151091). The Phase-1 F1 note is corrected the same way. - BZ1: MLT-8530 is rated 2.5-4.5 V but runs from 5V0. Now YX-SMD8530P (C781886), rated 2-5 V, with the same vendor land and pad-1 (+) corner. Schematic LCSC/MPN fields and BOM CSVs regenerated with common/bom.py. No footprint or layout change. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Ekhw9jYnrfxihP7yvxax5H
udaravima
marked this pull request as ready for review
September 27, 2026 15:55
Conflict: the Phase-1 F1 BOM note. PR #9 made the same correction in its own wording, so this keeps development's text. The manager rows are unchanged; BOMs regenerated and bom.py --check passes. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Ekhw9jYnrfxihP7yvxax5H
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Requested by Udara Vimarsha · project thread
Before: three manager BOM lines would order the wrong part. ENC1's LCSC number (C2831776) is a 100 µF/50 V electrolytic capacitor. F1's number (C3207114) is a clip for 6.35 mm tube fuses, which doesn't fit the board's direct-solder mini-blade land. BZ1 (MLT-8530) is rated 2.5–4.5 V but runs from 5V0.
After: each line now names a part that fits the existing land, so the layout doesn't change.
RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mmFuse_Blade_Mini_directSolder, so the fuse's own blades solder in with no holderSOURCING.md is updated to match. The Phase-1 F1 note got the same correction in #9, so the merge from development keeps #9's wording.
How: I edited
hardware/common/lcsc_parts.pyand ranpython3 common/bom.py, which rewrote the hidden LCSC/MPN/Manufacturer fields in the manager schematics and regenerated the BOM CSVs.bom.py --checkpasses. Schematic Value fields are unchanged, so BZ1 still reads "MLT-8530" on the board. I checked stock and pads against the JLCPCB and EasyEDA catalogues on 2026-09-27.Deferred (owner: "leave the big components"): these need land or layout changes and are not in this PR.
I also compared every footprint on the manager board and the backplane against its schematic field and library copy: all 504 pads match, so there is no stale footprint like the one found on Phase-1.
🤖 Generated with Claude Code
https://claude.ai/code/session_01Ekhw9jYnrfxihP7yvxax5H