2 changes: 1 addition & 1 deletion .github/ISSUE_TEMPLATE/bug_report.yml
Original file line number Diff line number Diff line change
Expand Up @@ -53,7 +53,7 @@ body:
attributes:
label: Firmware version
description: Shown in the connection bar.
placeholder: "v1.4"
placeholder: "v1.5"

- type: input
id: os
Expand Down
122 changes: 117 additions & 5 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -4,6 +4,118 @@ All notable changes to this project are documented here.
Format loosely follows [Keep a Changelog](https://keepachangelog.com/);
versioning follows [Semantic Versioning](https://semver.org/).

## [1.2.0] — 2026-08-21

### Added — a second way to measure

- **Probe-to-Photon.** A separate measurement mode, firmware **v1.5**. `t₀` is
the same probe contact on `D2`, taken in the same ISR; `t₁` is the first
KY-018 reading past a calibrated threshold. The dashboard's test mode shows a
black target area that turns white the instant Windows reports the click, and
the Teensy times the gap. Nothing is transmitted between t₀ and t₁, so the
serial round-trip offset is **not** subtracted — there is no round-trip.
- **Optical calibration, automatic and in the right place.** Entering test mode
in this mode calibrates first, inside the full-screen overlay, on the same
target the measurement uses: black, settle, sample, white, settle, sample.
A baseline taken anywhere else on the screen describes a different patch of
backlight and is worthless, so it is not left to the operator to get right.
The threshold is the midpoint and the direction is derived, so a module whose
ADC value falls as light rises works with no setting. Baselines closer than
60 ADC counts stop the run before it arms — a threshold inside the noise would
make every sample a coin toss. Each reading is taken 400 ms after the target
changes colour, because a photoresistor does not settle instantly. The side
panel keeps manual black/white buttons as a bench check on the sensor.
- **The two modes never mix.** Different wire token (`OPT:` vs `LAT:`),
different firmware statistics, `runs.mode` in the archive, and a warning in
the Compare tab when a comparison spans both. They do not measure the same
interval and the interface never pretends otherwise.
- **Schema v3.** `runs.mode`, `runs.optical_dark`, `runs.optical_bright`,
`runs.optical_threshold` and `samples.raw_optical`, added in place. Existing
runs read as `probe_to_pc`, which is what they are: it was the only mode that
existed when they were written.
- **The demo device speaks both modes**, so the whole optical flow — calibration,
target, samples, archive — can be exercised with no hardware attached.

### Honest about the sensor

- The KY-018 is a photoresistor. Its own response time is in the milliseconds,
the same order as the quantity being measured, and it drifts with ambient
light and temperature. Probe-to-Photon is documented as a **relative**
indicator — one setup against itself — and explicitly **not** as an absolute
click-to-photon benchmark. The dashboard says so in the optical panel, not
only in the README.
- The dashboard's own repaint is inside the measured interval, driven by a 1 ms
poll because touching a Tk widget from the input-listener thread is not safe.
Documented rather than hidden: click-to-photon includes the application.
- The ADC prescaler goes from /128 to /16 while the optical mode is active
(~13 µs per reading instead of ~112 µs), trading a little absolute accuracy
for finer timing — the right way round for a threshold crossing.

### Added — buttons that do something

- **BTN1 / BTN2 now do something.** The 10-press hardware acceptance test
passed, so the buttons are bound: `BTN1` enters and leaves test mode, `BTN2`
clears the live run while test mode is **not** running. Entirely
dashboard-side — the firmware is unchanged and still only *reports* the press,
so the dashboard stays the authority on session state and refuses a press that
would disturb a run (disconnected, calibrating, or `BTN2` during test mode).

### Fixed

- **The live tab's right-hand column scrolls.** With the optical panel showing it
was taller than a laptop screen, which put *Enter test mode* below the bottom
edge of the window with no way to reach it.
- **The optical target is large and in the same place in both windows.** It was
a 260 px square that the calibration window and the test overlay positioned
differently; a sensor held on the glass with elastic bands does not hit that,
and both baselines then came back identical. It is now a 620 × 440 block dead
centre, drawn by one function that both windows call. A failed calibration
stays on screen with a live LIGHT reading, several times a second, so the
sensor can be aimed by watching the number rather than by guessing; Enter
retries, Esc gives up.
- **The optical calibration happens where the measurement happens.** It used to
sample a small swatch in the side panel, then measure against a full-screen
target somewhere else entirely — different patch of backlight, so the
threshold described the wrong thing. There is now one button, it opens a
centred full-screen target, and entering test mode repeats the calibration on
that same target. The per-baseline buttons are gone: they only offered a way
to get it wrong.
- **A failed calibration reports the numbers it measured**, not just the limit
it missed — "dark 214, bright 226, 12 counts apart, at least 60 needed" tells
you whether the setup is nearly right or nowhere near.
- **"Access denied" on the COM port at startup.** Two causes, both addressed:
the serial reader thread is now joined when the port is closed, so Windows has
really released the handle before the process exits; and the automatic
connection at startup retries quietly instead of greeting the user with a
modal error. A connection the *user* asks for still reports its errors.

### Preserved

- The Probe-to-PC path in the v1.5 sketch is **byte-identical** to v1.4 and
v1.3: `probeISR()`, the t₀/t₁ block, the `TRIG`/`H` handshake,
`runCalibration()`, `serviceProbeRearm()`, every filter and the OLED freeze.
The diff from v1.4 removes six lines: three version strings, one comment, the
`if (probeFlag)` that became `} else if (probeFlag)`, and the OLED refresh
guard that now also checks the optical mode. Everything else is an addition.
- The mouse remains untouched: no opening it, no soldering to its PCB, no
transistor across its microswitch. Removable copper tape on the outside of the
button is still the only mouse-side modification, in this mode as in the other.

### Settled

- **The hardware is finished.** Every component is built, wired and verified;
nothing is waiting on hardware. What is left is a 3D-printed enclosure, which
changes no measurement.
- **The 2N2222A and the 220 Ω resistors are not needed.** They were on an early
parts list and never found a role — not in the probe method, which switches
nothing, and not in Probe-to-Photon, which reads a sensor that was already
wired. Documented as "do not buy" rather than left dangling as "reserved".
- **Probe-to-Photon verified on hardware:** 40 clicks, ~16 ms median against
~3 ms for the same mouse in Probe-to-PC. The ~13 ms difference is the display
pipeline *and* the KY-018's own response together, and is documented as such.

---

## [1.1.0] — 2026-08-19

### Added — knowing which mouse is plugged in
Expand Down Expand Up @@ -152,11 +264,11 @@ exactly as in the last known-good internal build.

### Not implemented

- Physical button *behaviour* (BTN1 = test mode, BTN2 = reset the live run) —
planned, gated on the 10-press hardware acceptance test.
- 2N2222A transistor and its 220 Ω resistor — physically present, deliberately
**not connected**, no firmware, no protocol, purpose not specified.
- Any photoresistor-based measurement mode — does not exist.
- 2N2222A transistor and the 220 Ω resistors — **not used at all**, settled: the
finished tester has no role for them.
- **Probe-to-Photon mode** — specified, not implemented. Design recorded in the
README; no firmware, no protocol token, no UI. It will be a separate mode from
Probe-to-PC and will not alter the existing timing path.

---